SFA1200AJ – Module de télémétrie laser de qualité industrielle à impulsion unique de 905 nm, TOF 1 200 m

To begin with, the SFA1200AJ adopts 905nm semiconductor pulse laser technology and operates on single-pulse TOF (Time-of-Flight) ranging principles. As a result, it delivers stable full-scale ranging from 5m to 1200m. Furthermore, it combines Class 1 eye safety, a lightweight compact design, industrial‑grade reliability, and low power consumption for extended battery life. Consequently, it provides a professional solution for UAV aerial surveying, security perimeter warning, industrial automation monitoring, vehicle‑mounted optoelectronic devices, and other medium‑to‑long range high‑reliability applications.


I. Single-Pulse TOF: The Preferred Technology for Medium‑to‑Long Range High‑Reliability Applications

To begin with, the SFA1200AJ leverages the proven single‑pulse TOF laser ranging principle. Additionally, it integrates an opto‑mechanical‑electronic compact design with high‑sensitivity APD detection technology. As a result, it offers clear advantages over traditional ranging solutions in medium‑to‑long range industrial scenarios:

  • Avant toute chose, Il offre une portée de 1 200 m, assurant une couverture stable sur des cibles de type 70% (bâtiments réfléchissants) et pouvant atteindre 1 500 m sur des cibles à haute réflectivité.
  • Par ailleurs, it emits 905nm near‑infrared invisible light, achieves Class 1 eye‑safe certification (IEC 60825‑1), and maintains an average laser power of 8.23mW – therefore imposing no usage restrictions in open civilian environments.
  • De plus, Il offre une protection IP67 contre la poussière et l'eau, garantissant ainsi un fonctionnement fiable à long terme sous la pluie, dans la poussière, en milieu humide et dans d'autres conditions extérieures difficiles.
  • Par ailleurs, it provides excellent mechanical shock resistance – withstanding 1000g/ms shock (10 times/s along the optical axis) and 2.5g wide‑frequency vibration, making it suitable for vehicle‑mounted and airborne applications.
  • Par ailleurs, Il fonctionne sur une large plage de températures – il reste stable entre -20 °C et +60 °C et peut être stocké entre -25 °C et +75 °C, ce qui lui permet de s'adapter à des conditions climatiques très variées.
  • Il convient notamment de noter que, it features a low false‑alarm design – incorporating a built‑in intelligent anti‑interference algorithm that achieves hit rate ≥98% and false‑alarm rate ≤1%, thus avoiding false triggers in complex environments.
  • Enfin, Il prend en charge des modes de mesure flexibles, offrant une mesure ponctuelle ou en continu avec des intervalles personnalisables pour répondre à divers besoins de test.

II. Spécifications techniques essentielles

To begin with, the SFA1200AJ achieves a ranging capability of 1200m (at 70% reflective building target, visibility ≥6km) and a minimum range of 5m (at 90% reflective whiteboard). Furthermore, it delivers ranging accuracy of ±0.7m for distances ≤100m, and ±(0.7 + 0.004×d) m for distances >100m. Additionally, it offers a measurement frequency of 3Hz for continuous measurement of the same target, and 2Hz when switching between different targets. Moreover, it maintains a hit rate of ≥98%, with a false‑alarm rate of ≤1%.

In terms of physical design, the module features a cylindrical integrated form factor with dimensions of Φ23mm × 40mm and a weight of 22 ± 0.5g. Consequently, it is easy to install and integrate into various optoelectronic devices.

Regarding environmental adaptability, the module operates from ‑20°C to +60°C and stores from ‑25°C to +75°C. Its MTBF is ≥1500 hours, ensuring long‑term stable operation.

For power requirements, we specify the supply voltage as DC 3.3V ± 0.1V. Standby power consumption is ≤400mW (Power on low) and ≤1mW (Power on high, deep sleep). Operating power is ≤1.3W at ‑20°C, ≤1.5W at 25°C, and ≤1.8W at 70°C – consequently, this low power consumption extends battery life of portable devices.

Furthermore, the module supports single‑shot and continuous ranging mode switching, LD continuous‑on calibration mode, power‑on self‑test, and abnormal status reporting. For communication, we equip it with a standard UART (TTL_3.3V) serial interface, with a default baud rate of 115200bps, adjustable across 9600–230400bps. Moreover, we provide a complete communication protocol and dedicated PC‑based testing software, enabling low‑threshold secondary development.

(Données basées sur des conditions standard : ligne de visée, visibilité ≥ 6 km, humidité relative ≤ 70%, réflectivité de la cible ≥ 0,7. Une réflectivité inférieure ou des conditions environnementales défavorables peuvent réduire la portée effective.)


III. Couverture complète des applications

  • UAV Aerial Surveying & Obstacle Avoidance: To begin with, the module serves surveying UAVs, inspection UAVs, and agricultural UAVs. Its 1200m range covers large operational areas, and its lightweight design adds minimal flight load.
  • Security Perimeter Warning: Secondly, it supports campus perimeters, border security, and critical facility protection – enabling long‑range intrusion detection with precise trigger alarms.
  • Industrial Automation Monitoring: Thirdly, it facilitates level measurement, object positioning, and production line collision avoidance. Its stable and reliable operation improves production efficiency.
  • Dispositifs optoélectroniques embarqués : Fourthly, it integrates into unmanned vehicles, patrol vehicles, and special‑purpose vehicles – providing real‑time ranging and target tracking while adapting to vehicle vibration environments.
  • Appareils de mesure portables : Additionally, it serves long‑range laser rangefinders, telescope integration, and outdoor exploration gear – offering lightweight portability with extended battery life.
  • Engineering Surveying & Mapping: Furthermore, it supports terrain mapping, construction surveying, and geological exploration. Its high‑precision data output ensures project quality.
  • Forces de l'ordre et secours d'urgence : Finally, it assists in crime scene investigation, distance measurement, and rescue positioning – enabling rapid response and improving operational efficiency.

IV. Consignes d'utilisation

Sécurité : Tout d'abord, ce produit est un laser de classe 1 sans danger pour les yeux. Nous vous recommandons toutefois d'éviter de regarder directement et de manière prolongée l'ouverture du laser afin de prévenir toute fatigue oculaire potentielle. Par ailleurs, le mode d'étalonnage du spot est réservé à l'usage des développeurs ; ne dirigez pas le laser vers les yeux d'une personne lorsque ce mode est activé.

Protection contre les décharges électrostatiques : Additionally, we require proper electrostatic discharge precautions. Do not touch any electronic components without appropriate protective measures. Never connect or disconnect cables while the module is powered on. Moreover, ensure correct power polarity and that the voltage remains within 3.3V ± 0.1V; failure to do so may cause irreparable damage.

Entretien des vitres optiques : Furthermore, keep the optical lens clean. Use a blower to remove dust particles. For fingerprints, gently wipe with a cotton swab dipped in a small amount of alcohol‑ether mixture, then clean with a lens cloth. Do not touch the optical surface directly with fingers. For the optical window, we recommend using H‑K9L optical glass coated with an 855nm–955nm anti‑reflection coating (transmittance ≥99.5%).

Précautions environnementales : In addition, we advise avoiding prolonged use in high‑temperature, high‑humidity, highly corrosive, or strong electromagnetic interference environments. Furthermore, protect the module from rapid temperature changes or strong mechanical shocks.

Modification et câblage : Par ailleurs, ne démontez pas, ne modifiez pas et n’altérez pas le module, car cela entraînerait l’annulation de la garantie. Utilisez le câble de communication à 6 broches d’origine fourni. Si vous utilisez un câble personnalisé, vérifiez que l’affectation des broches est correcte afin d’éviter une inversion des broches TX/RX, ce qui pourrait provoquer des erreurs de communication.

Démarrage et gestion de l'alimentation : Finally, allow approximately 500ms after power‑on for system initialisation. Pull the enable pin low before sending ranging commands. To exit deep sleep mode, pull the enable pin high; the wake‑up response time is ≤10ms.


Conclusion

In conclusion, the SFA1200AJ combines 1200m long range, 22g lightweight design, IP67 full protection, industrial‑grade durability, and low power consumption. Therefore, it serves as an ideal high‑performance ranging component for a wide range of medium‑to‑long range industrial measurement and embedded integration needs. From UAVs and security systems to industrial automation and vehicle‑mounted optoelectronics, the SFA1200AJ empowers smart sensing to reach farther, operate more stably, and deliver greater reliability.

Partagez votre amour

Laisser un commentaire

Votre adresse e-mail ne sera pas publiée. Les champs obligatoires sont indiqués avec *